Autonics Multi-Functional Digital Indicators KN-2201W-Peak
Category: Controller
Specifications
Weight(gram)
100
Dimension
5 cm (Length) x 4 cm (Width) x 5 cm (Height)
Details
Autonics Multi-Functional Digital Indicators KN-2201W-Peak ( With Peak Mode Holding Function)
Main features
• High accuracy with 16bit ADC (±0.2% F.S.)
• Max. display range: 19999 to 19999
• Multi-input
: Thermometer 12 types, RTD 5 types, analog (mV, V, mA) 6 types
• Auto display color change function (for error or alarm)
• Various output options : 4EA or 2EA alarm output, 4-20 mA transmission output (isolated), RS485 communication output
※ Full output option model is available.
(alarm output 4EA + RS485 communication output + transmission output)
• Various functions
: High/Low peak monitoring, sensor break alarm output (burn-out), input correction, digital input (DI), user input range, display scale, transmission output scale, etc.
• Built-in power supply for sensor (24 VDC)
Specification Table
Series | KN-2000W | |
Power supply | AC voltage | 100-240 VAC 50 to 60 Hz |
DC voltage | 24 VDC | |
Allowable voltage range | 90 to 110% of rated voltage | |
Power consumption | AC voltage | Max. 8 VA |
DC voltage | Max. 3 W | |
Display method | 4 1/2 digit: 7 Segment LED Display (selectable red, green, yellow), character size : W10 mm x H17 mm | |
Input type | RTD | JPt100Ω, DPt100Ω, DPt50Ω, Cu50Ω, Cu100Ω (5 types) |
Thermocouple | K, J, E, T, R, B, S, N, C (W5), L, U, PLII (12 types) | |
Analog | • Voltage : ±1.0000 V, ±50.00 mV, ±200.0 mV, -1.000 V~10.000 V (4 types) • Current : 4.00~20.00 mA, 0.00-20.00 mA (2 types) |
|
Digital input | • Contact input : Max. 2 kΩ in ON,Max. 90 kΩ in OFF • Non-contact input: Residual voltage max. 1.0 V in ON, Leakage current max. 0.03 mA in OFF • Outflow current: Approx. 0.2 mA |
|
Sub output | Alarm output | 2-point: Relay contact capacity 250 VAC 3 A 1c, 4-point: Relay contact capacity 250 VAC 1 A 1a |
Transmission output | ISOLATED DC 4-20 mA (PV transmission) load resistance max. 600Ω (accuracy: ±0.2%F.S., resolution: 8000) |
|
Communication output | RS485 (Modbus RTU) | |
Display accuracy | ±0.2% F.S. ±1digit (25±5℃) ±0.3% F.S. ±1digit (-10 to 20℃, 30 to 50℃) In case of thermocouple and below -100℃ input, [ ±0.4% F.S. ]±1digit ※TC-T, TC-U is min. ±2.0℃ |
|
Setting method | Set by front keys, or RS485 communication | |
Alarm output hysteresis | Set ON/OFF interval (1 to 999 digit) | |
Sampling cycle | Analog input: 100 ms, Temperature sensor input: 250 ms | |
Dielectric voltage | 200 0VAC 50/60 Hz for 1 min. (between input terminal and power terminal) | |
Vibration | 0.75 mm amplitude at frequency of 5 to 55 Hz (for 1 min.) in each of X, Y, Z directions for 2 hours | |
Relay life cycle | 2-point | Mechanical: Min. 10,000,000, Electrical: Min. 100,000 (250 VAC 3 A resistance load) |
4-point | Mechanical: Min. 20,000,000, Electrical: Min. 500,000 (250 VAC 1 A resistance load) | |
Insulation resistance | Min. 100 MΩ (at 500VDC megger) | |
Noise resistance | Square shaped noise by noise simulator (pulse width 1 ㎲) ±2 kV | |
Memory retention | Approx. 10 years (non-volatile semiconductor memory type) | |
Environ- ment | Ambient temperature | -10 to 50℃, storage: - 20 to 60℃ |
Ambient humidity | 35 to 85%RH, storage: 35 to 85%RH | |
Approval | CE | |
Unit weight | Approx. 200 g |
.jpg)
.jpg)
.jpg)
Caution For Your Safety
• For connecting the power, use a crimp terminal(M3.5, min. 7.2 mm).
• The connection of this unit should be separated from the power line and high voltage line in order to prevent inductive noise.
• Install a power switch or a circuit breaker to supply or cut off the power.
• Switch or circuit breaker should be installed nearby users for convenient control.
• Do not use this unit near the high frequency instruments (high frequency welding machine & sewing machine, large capacity SCR controller).
• When supplying input, if HHHH or LLLL is displayed, measured input may have problem. Turn off the power and check the line.
• Installation environment.
① It shall be used indoor.
② Pollution Degree 2
③ Altitude max. 2,000 m
④ Installation category Ⅱ
• It may cause malfunction if above instructions are not followed